QCM-Based HCl Gas Sensors Using Spin-Coated Aminated Polystyrene Colloids

采用旋涂胺化聚苯乙烯胶体的 QCM 型 HCl 气体传感器

阅读:9
作者:Young-Jae Jin, Jinyoung Park

Abstract

Hydrogen chloride (HCl) gas is highly toxic to the human body. Therefore, HCl gas detection sensors should be installed at workplaces where trace HCl gas is continuously generated. Even though various polymer-based HCl-gas-sensing films have been developed, simpler and novel sensing platforms should be developed to ensure the cost effectiveness and reusability of the sensing platforms. Therefore, we present a simple strategy to fabricate reusable HCl-gas-sensing platforms using aminated polystyrene (a-PS) colloids and investigate their sensitivity, reusability, and selectivity using a quartz crystal microbalance (QCM). The reusable a-PS(1.0) colloidal sensor with a high degree of amination (DA) exhibited the highest binding capacity (102 μg/mg) based on the frequency change (Δf) during the HCl gas adsorption process. Further, its sensitivity and limit of detection (LOD) were 3.88 Hz/ppm and 5.002 ppm, respectively, at a low HCl gas concentration (<10 ppm). In addition, the sensitivity coefficient (k*) of the a-PS(1.0) colloid sensor with respect to HCHO was higher than that in the case of HF because of the lower binding affinity of the former with the a-PS(1.0) colloids. Based on these results, highly sensitive and reproducible a-PS colloids could be reused as an HCl-gas-sensing platform and used as an HCl sorbent in a gas column filter.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。