Cytokine detection and simultaneous assessment of rheumatoid factor interference in human serum and synovial fluid using high-sensitivity protein arrays on plasmonic gold chips

使用等离子体金芯片上的高灵敏度蛋白质阵列检测细胞因子并同时评估人类血清和滑液中的类风湿因子干扰

阅读:11
作者:Manfè Valentina, Fleckner Jan, Nørby Lisby Peder, Zhang Bo, Dai Hongjie, Keller Pernille

Background

Fluorescence-enhancing microarray on plasmonic gold film is an attractive alternative to traditional enzyme-linked immunosorbent assay (ELISA) for cytokine detection because of the increased sensitivity. The assay chemistry is similar to an ELISA sandwich assay, but owing to the gold substrate, cytokine measurements are 10 to 100 times more sensitive and can be multiplexed. Plasmonic protein microarrays are, as other immunoassays, affected by the presence of heterophilic antibodies and rheumatoid factor may lead to analytical errors with serious implications for patient care. Here, we present a plasmonic gold substrate protein microarray for high-sensitivity detection of cytokines with simultaneous assessment of rheumatoid factor interference on a single chip.

Conclusion

Using novel plasmonic gold chips, we developed a highly sensitive and accurate assay platform to detect lowly expressed cytokines in biological fluids, allowing for the elimination of rheumatoid factor interference in as little as 5 μl sample volume. The detection limit was below 1 pg/ml for IL-20 and linearity was achieved over a 5-log dynamic range. This technology is highly advantageous for cytokines where sensitivity or sample volume is critical or where assessment of rheumatoid factor interference needs addressed and eliminated.

Results

Paired serum and synovial fluid samples from patients with rheumatoid arthritis (n = 18), osteoarthritis (n = 9) or healthy controls (n = 10) were arrayed on near-infrared fluorescence enhancing plasmonic gold chips spotted with cytokine-specific capture antibody and isotype control antibody. Possible rheumatoid factor interference was visualised by a non-specific signal from the isotype control antibody, and pre-treatment of samples with heat-aggregated animal IgG eliminated this background contamination. The platform was optimised using the cytokine IL-20. The protein microarray platform allowed for the detection of human IL-20 at levels <1 pg/ml with reliable IL-20 quantification over a 5-log dynamic range. Samples for which rheumatoid factor caused artefacts were identified and a method for eliminating rheumatoid factor interference was developed and validated. IL-20 protein levels were significantly higher in synovial fluid samples from patients with rheumatoid arthritis compared to osteoarthritis (p < 0.001), while serum levels of IL-20 did not differ between patients with rheumatoid arthritis, osteoarthritis or healthy controls.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。