A diagnostic accuracy study comparing RNA LAMP, direct LAMP, and rapid antigen testing from nasopharyngeal swabs

一项比较 RNA LAMP、直接 LAMP 和鼻咽拭子快速抗原检测的诊断准确性研究

阅读:7
作者:Guojun Cao, Ke Lin, Jingwen Ai, Jianpeng Cai, Haocheng Zhang, Yiqi Yu, Qihui Liu, Xinyun Zhang, Yi Zhang, Zhangfan Fu, Jieyu Song, Hongyu Wang, Guanmin Yuan, Sen Wang, Ming Guan, Wenhong Zhang

Conclusion

The LAMP assay are suitable for mass screenings of SARS-CoV-2 infections in the general population.

Methods

We used 860 nasopharyngeal specimens from healthcare workers of Huashan Hospital and COVID-19 patients collected from April 7th to 21st, 2022, to assess the clinical diagnostic performance of the LAMP assay marketed by Shanghai GeneSc Biotech and compared it to the result of a rapid antigen test (RAT) head-to-head.

Results

Overall, the diagnostic performance of LAMP assay and RAT were as follows. The LAMP assay represented higher sensitivity and specificity than RAT, especially in the extracted RNA samples. The sensitivity was 70.92% and 92.91% for direct LAMP and RNA-LAMP assay, respectively, while the specificity was 99.86% and 98.33%. The LAMP assay had overall better diagnostic performance on the specimens with relatively lower C t values or collected in the early phase (≤7 days) of COVID-19. The combination of LAMP assay and RAT improved diagnostic efficiency, providing new strategies for rapidly detecting SARS-CoV-2.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。