Fabrication of a Microfluidic Test Device with a 3D Printer and Its Combination with the Loop Mediated Isothermal Amplification Method to Detect Streptococcus pyogenes

利用 3D 打印机制作微流控测试装置及其与环介导等温扩增方法结合检测化脓性链球菌

阅读:15
作者:Hayriye Kirkoyun Uysal, Meltem Eryildiz, Mehmet Demirci

Abstract

New rapid, reliable, and cost-effective alternative systems are needed for the rapid diagnosis of Streptococcus pyogenes. The aim of this study was to fabricate a microfluidic test device to detect Streptococcus pyogenes by combining the Loop-mediated isothermal amplification method via a 3D printer. Microfluidic test devices were designed in CATIA V5 Release 16 software, and data were directly transferred to a 3D printer and produced using the FDM method with biocompatible PLA filament. The S. pyogenes ATCC 19615 and different ATCC strains was used. Following identification by classical culture methods, a 0.5 McFarland suspension was prepared from the colonies, and DNA isolation was performed from this liquid by a boiling method. S. pyogenes specific speB gene was used to desing LAMP primer sets in PrimerExplorer V5 software and tested on a microfluidic device. LAMP reactions were performed on microfluidic device and on a microcentrifuge tube separately. Both results were analyzed using the culture method as the standard method to diagnostic values. Melting curve analysis of the amplicons of the LAMP reactions performed on a LightCycler 480 system to detect amplification. Among the 50 positive and 100 negative samples, only four samples were found to be false negative by LAMP reaction in a microcentrifuge tube, while eight samples were found to be false negative by LAMP reaction on a microfluidic device. Six samples were found to be false positive by the LAMP reaction in the microcentrifuge tube, while ten samples were found to be false positive by the LAMP reaction on a microfluidic chip. The sensitivity, specificity, positive predictive value, and negative predictive value of the LAMP reactions performed in the microcentrifuge tube and on the microfluidic device were 92-84%, 94-90%, 88.46-80.77%, and 95.92-91.84%, respectively. The limit of detection (LOD) was found to be the same as 1.5 × 102 CFU/mL and the limit of quantification (LOQ) values of the LAMP reactions were performed on the microcentrifuge tube and on the microfluidic device were 2.46 × 102-7.4 × 102 CFU/mL, respectively. Cohen's kappa (κ) values of the LAMP reactions were performed on the microcentrifuge tube and on the microfluidic device were 0.620-0.705, respectively. In conclusion, our data showed that the LAMP method can be combined with microfluidic test device to detect S. pyogenes, this microfluidic device can be manufactured using 3D printers and results are close to gold standard methods. These devices can be combined with LAMP reactions to detect different pathogens where resources are limited and rapid results are required.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。