Simultaneous determination of ezetimibe and simvastatin in rat plasma by stable-isotope dilution LC-ESI-MS/MS and its application to a pharmacokinetic study

稳定同位素稀释液相色谱-电喷雾串联质谱法同时测定大鼠血浆中的依折麦布和辛伐他汀及其在药代动力学研究中的应用

阅读:13
作者:Sireesha R Karanam, Prakash Katakam, Babu R Chandu, Nagiat T Hwisa, Shanta K Adiki

Abstract

A simple, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed for simultaneous quantification of ezetimibe and simvastatin in rat plasma. The deuterium isotopes: ezetimibe d4 and simvastatin d6 were used as internal standards for ezetimibe and simvastatin, respectively. MS/MS detection involved a switch of electron spray ionization mode from negative to positive at retention time 3.01 min. Samples were extracted from plasma by liquid-liquid extraction using tertiary butyl methyl ether. Chromatographic separation was achieved with Agilent Eclipse XBD-C18 column using mobile phase that consisted of a mixture of ammonium acetate (pH4.5; 10 mM)-acetonitrile (25:75 v/v). The method was linear and validated over the concentration range of 0.2-40.0 ng/mL for simvastatin and 0.05-15.0 ng/mL for ezetimibe. The transitions selected were m/z 408.3→271.1 and m/z 412.0→275.10 for ezetimibe and ezetimibe d4, and m/z 419.30→285.20 and m/z 425.40→199.20 for simvastatin and simvastatin d6. Intra- and inter-batch precisions for ezetimibe were 1.6-14.8% and 2.1-13.4%; and for simvastatin 0.94-9.56% and 0.79-12%, respectively. The proposed method was sensitive, selective, precise and accurate for the quantification of ezetimibe and simvastatin simultaneously in rat plasma. The method was successfully applied to a pharmacokinetic study by oral co-administration of ezetimibe and simvastatin in SD rats.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。