Conclusions

Assays for these CSF analytes demonstrate consistent sensitivity, reliability, and biotemporally stability for use in a multiple pathophysiological CSF biomarker panel to profile AD. Their qualification enables further investigation for use in AD diagnosis, staging and progression, disease mechanism profiling, and clinical trials.

Methods

Paired baseline and eight-week CSFs from twenty participants in a clinical drug trial for mild cognitive impairment (MCI) or mild dementia due to AD were used to evaluate sensitivity, intra-assay precision, inter-assay replicability, and eight-week biotemporal stability for sixty unique analytes measured with commercially available single- and multi-plex ELISA assays. Coefficients of variation (CV) were calculated, and intraclass correlation and Wilcoxon signed rank tests were applied.

Objective

Alzheimer's disease (AD) is a complex neurodegenerative disease driven by multiple interacting pathophysiological processes that ultimately

Results

We identified 32 biomarker candidates with good to excellent performance characteristics according to assay technical performance and CSF analyte biotemporal stability cut-off criteria. These included: 1) the core AD biomarkers Aβ1-42, Aβ1-40, Aβ1-38, and total tau; 2) non-Aβ, non-tau neurodegeneration markers NfL and FABP3; 3) inflammation/immune modulation markers IL-6, IL-7, IL-8, IL-12/23p40, IL-15, IL-16, MCP-1, MDC, MIP-1β, and YKL-40; 4) neurovascular markers Flt-1, ICAM-1, MMP-1, MMP-2, MMP-3, MMP-10, PlGF, VCAM-1, VEGF, VEGF-C, and VEGF-D; and 5) metabolism/oxidative stress markers 24-OHC, adiponectin, leptin, soluble insulin receptor, and 8-OHdG. Conclusions: Assays for these CSF analytes demonstrate consistent sensitivity, reliability, and biotemporally stability for use in a multiple pathophysiological CSF biomarker panel to profile AD. Their qualification enables further investigation for use in AD diagnosis, staging and progression, disease mechanism profiling, and clinical trials.