Monitoring the extraction of copper from chicken dung leachate using an aluminium electrode as an indicator

以铝电极为指示剂监测鸡粪渗滤液中铜的提取

阅读:8
作者:Peterson Mutembei Kugeria, Isaac Waweru Mwangi, Jackson Wachira Muthengia, Peter Waithaka Njoroge

Abstract

Copper is found in several minerals in the earth's crust with varying the elemental and mineralogical composition. Several techniques of extraction have been investigated all in the effort of obtaining a cheaper and viable method. This paper reports on further works done on copper extraction using a wet chemical method. According to the method, reduction of copper (II) ions using hydrazones from chlorinated chicken waste leachate was stoichiometrically driven. The chicken dung leachate used was an impure bio-material in which the concentration could not be determined. It was, therefore, difficult to quantify the stoichiometric ratios of species in that reaction. This paper reports on a method of monitoring the extent of copper reduction by chlorinated chicken dung leachate using an aluminum electrode as an indicator. Mineral rocks were obtained from Maragwa Location in Tharaka Nithi County in Kenya. The samples were ground into a fine powder of 250 micro millimeters. The samples were then subjected to mineralogical analysis using X-ray diffraction (XRD). Chemical analysis was done using atomic absorption spectroscopy (AAS) and X-ray fluorescence spectroscopy (XRFS). Ground samples were leached using 1.0 M hydrochloric acid. The resulting leachate was treated with chicken dung leachate prepared from chicken dung in which chlorine gas was bubbled at a constant temperature of 28 °C. The pH of the resultant chicken dung leachate was adjusted from 4 to 12 using 1.0 M sodium hydroxide and then used as an electrolyte. An electrochemical cell was set up consisting of aluminum and graphite rods. The aluminum electrode was found not to corrode at pH above 11 while it was able to displace available copper ions. This property of the aluminum electrode was used to monitor when all copper ions were displaced. The recovered copper was analyzed using XRFS. The copper recovery rate from the samples ranged from 7.0 to 20.0 at level A and 7.4-26.8% at level B with a purity range of 84.9 level A to 88.6% level B. An overall positive potential in the reduction process confirmed the greater the tendency of copper reduction without an external source of electricity. The corrosion of the aluminium electrode in the process was not observed and therefore does not require frequent replacement. Therefore, a large scale extraction process needs to be investigated.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。