Quality-control method for the determination of biological activity of engineered calcineurin subunit B

工程化钙调磷酸酶亚基B生物活性测定的质量控制方法

阅读:9
作者:Xinchang Shi, Huan Yang, Li Xu, Xiang Li, Zongwen Huang, Yudong Han, Qun Wei, Chunming Rao

Abstract

The aim of this study was to establish a quality-control method for calcineurin subunit B (CNB) biological activity determinations. CNB enhances the p-nitrophenylphosphate (pNPP) dephosphorylating activity of calcineurin subunit A Δ316 mutant (CNAΔ316). A series of CNB concentrations were fitted to a four-parameter equation to calculate the corresponding pNPP maximum dephosphorylation rates. Values were calculated based on biological activity references using a parallel line method. The method was then validated for accuracy, precision, linearity, linear range, sensitivity, specificity, and robustness. The recovery results were greater than 98%. Intra-plate precision was 6.7%, with inter-plate precision of 10.8%. The coefficient of determination was greater than 0.98. The linear range was 0.05-50 μg mL(-1), with sensitivity of 50 μg mL(-1). Tested cytokines did not induce CNAΔ316 dephosphorylation of pNPP. The chosen CNAΔ316 concentration range did not affect activity determinations.